The U.S. LNG industry continues to grow, particularly along the Gulf Coast. U.S. LNG exports averaged 17.4 bcfd during the first half of 2026, 23% higher than the same period in 2025.
The U.S. EIA estimates exports will average approximately 17.3 bcfd during the second half of 2026, while U.S. LNG export capacity is projected to reach 27.7 bcfd by 2030. That growth means more contractors and employees moving from construction to commissioning, startup, maintenance and operation around hydrocarbon systems.
From an FR clothing standpoint, one of the primary concerns is short-duration thermal exposure from fire, including flash fire.
LNG itself is not flammable in its liquid state. The hazard develops when LNG vaporizes and the resulting natural gas mixes with air in its flammable range. PHMSA (Pipeline and Hazardous Materials Safety Administration) identifies that range as approximately 5 to 15% LNG vapor in air. If a vapor cloud in that range reaches an ignition source, a flash fire can occur. PHMSA also notes that a flash fire can burn back toward the release point and result in a pool fire or jet fire depending on the release.
FR clothing does not prevent that release or ignition. It is secondary PPE. Process design, gas detection, isolation, shutdown systems, operating procedures and safe work practices are intended to prevent or limit the event. FR clothing is there when those controls do not fully prevent a worker from being exposed to flame and thermal energy.
Conventional clothing can ignite and continue to burn after the original flame exposure is gone. Flame-resistant clothing is designed to resist ignition and self-extinguish when the ignition source is removed. It can also reduce heat transfer to the body. The goal is to keep the worker's clothing from becoming additional fuel and reduce the potential severity of a burn injury.
For LNG and petrochemical facilities with an identified short-duration thermal hazard, NFPA 2112 should be a starting point for garment selection. NFPA 2112-2023, Standard on Flame-Resistant Clothing for Protection of Industrial Personnel Against Short-Duration Thermal Exposures from Fire, establishes design, performance, testing, labeling and certification requirements for protective garments. NFPA 2112 also requires third-party certification.
One of the better-known parts of NFPA 2112 is the instrumented manikin test using ASTM F1930. A standardized test garment is exposed to a controlled thermal exposure and predicted body burn is calculated from sensors on the manikin. NFPA 2112 requires an average predicted body burn of not more than 50%, with no single result equal to or greater than 55% based on the area covered by the sensors, excluding the hands and feet.
The NFPA 2112 technical committee has been very clear that the manikin test is one part of the standard and is intended as a material qualification test. It is not proof of how a specific finished garment will perform in every real-world fire.
That distinction matters in LNG. A real release is not a laboratory exposure. PHMSA notes that the distance and behavior of an LNG vapor cloud depend on factors including release volume, duration, wind direction and velocity, terrain, temperature and humidity.
This is also where NFPA 2113 becomes important. NFPA 2113-2025 is the Standard on Selection, Care, Use, and Maintenance of Flame-Resistant Garments for Protection of Industrial Personnel Against Short-Duration Thermal Exposures from Fire. NFPA 2113 gives the employer guidance on selecting, using, caring for and maintaining that garment in the field, where it must perform.
However, a certified garment by itself is not an FR program. The employer still has to determine where FR is required, who is exposed, how garments are worn, what other clothing is allowed with them, how they are cleaned, how damage is inspected, what repairs are acceptable and when a garment must be removed from service.
OSHA 29 CFR 1910.132 requires protective clothing to be provided, used and maintained in a sanitary and reliable condition when it is necessary because of workplace hazards.
OSHA has also addressed laundering of FR clothing directly. In a 2015 interpretation, OSHA stated that employers remain responsible for ensuring FR garments are adequately maintained so they will perform as designed. Where employees launder garments themselves, OSHA states that employers must provide proper laundering training and regularly inspect the clothing to determine whether repair or replacement is necessary.
The construction-to-commissioning transition deserves particular attention in the developing LNG market. During construction, large numbers of contractors and employees may be installing equipment before hydrocarbons are present. As systems are completed and commissioning begins, the exposure can change. Natural gas can be introduced into portions of a facility while construction, punch-list work and contractor activity continue elsewhere.
That transition needs a defined FR strategy. The operator needs to determine when FR requirements take effect, which areas and tasks are covered, what minimum garment standard applies and how contractors will be brought into that requirement. This needs to happen before hydrocarbons are introduced, not after.
Contractor consistency is also one of the places where FR programs can become unnecessarily complicated. One contractor may issue NFPA 2112-certified shirts and pants. Another may use NFPA 2112-certified coveralls. Another may arrive with garments simply labeled "FR" without clear documentation establishing NFPA 2112 compliance.
The answer is to establish a minimum performance requirement. If a facility has identified a short-duration thermal hazard and selected NFPA 2112 as its protective clothing standard, then the specification should identify NFPA 2112-compliant garments rather than simply stating "FR clothing."
The Gulf Coast adds another practical issue that cannot be ignored: heat and humidity. NIOSH and ACGIH recognize clothing and PPE as part of the total heat burden on a worker. However, traditional single-layer work clothing, including a long-sleeve shirt and pants or woven cloth coveralls, carries a clothing adjustment factor of 0 degrees Celsius when calculating effective WBGT. The larger concern is the total system: workload, humidity, radiant heat, acclimatization, hydration and any additional PPE or layers being worn.
Contamination is another LNG and petrochemical concern. FR does not mean that a garment cannot become contaminated with something that will burn. OSHA specifically identifies contaminants such as oils as something that can affect the performance of FR garments and places responsibility on the employer to ensure garments are adequately maintained.
Garments with combustible contamination need to be removed from service and properly cleaned. If the contamination cannot be adequately removed, the garment should not simply be returned to service because the label still says FR. Good-quality FR garments do not have an expiration date, but that does not mean they last forever. Fabric can wear thin. Seams can fail. Closures can break. Holes and abrasion can reduce coverage. When the garment's protective condition cannot be restored with confidence, replacement is the better decision.
The approach does not need to be complicated. Identify the short-duration thermal hazard. Use NFPA 2112-compliant garments as the performance baseline where that protection is required. Use NFPA 2113 for guidance on the proper selection, use, care and maintenance of those garments. Establish the same minimum performance expectation for contractors. Address the transition from construction into commissioning before hydrocarbons are introduced. Train workers on why the clothing is required and how it has to be worn and maintained.
FR clothing remains the last line of defense. It should never replace prevention, process management, safety protocols or good operating practices. But if a flash fire occurs, what the worker is wearing can affect the severity of the outcome. That is the reason to get the FR program right before it is needed.
For more information, visit bulwark.com.